Office Address:
Shreejaya Laboratories Pvt. Ltd., Plot No. 11 Sy.No.342 , ALEAP Industrial Area, Near Pragathi Nagar, Hyderabad-500 090.
2-Chloromethyl 3,5-Dimethyl 4-Methoxy Pyridine Hydrochloride |
CAS No.86604-75-3
| |||||||||||||||
| |||||||||||||||
Description | A light brown to off white color crystalline powder |
Identification by HPLC | The RT of the Major peak in the chromatogram of the test sample should correspond to that of working standard.. |
Chromatographic Purity By HPLC | |
Purity | Not less than 99.00% |
. Product Identification
|
3.1 Classification of the substance or mixture Classification according to Regulation (EC) No 1272/2008 For the full text of the H-Statements mentioned in this Section, see Section 16. Classification according to EU Directives 67/548/EEC or 1999/45/EC Not available For the full text of the R-phrases mentioned in this Section, see Section 16. 3.2 Label elements Labelling according Regulation (EC) No 1272/2008 Hazard statement(s) Precautionary statement(s) Supplemental Hazard Statements None
4.1 Description of first aid measures
General advice: Consult a physician. Show this safety data sheet to the doctor in attendance.
If inhaled: If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician
In case of skin contact: Wash off with soap and plenty of water. Consult a physician.
In case of eye contact: Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
If swallowed: Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
4.2 Most important symptoms and effects, both acute and delayed
The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in section 11
4.3 Indication of any immediate medical attention and special treatment needed:
No data available
5.1. Extinguishing media:
Suitable extinguishing media Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
5.2. Special hazards arising from the substance or mixture: carbon dioxide, nitrogen oxides (NOx), Hydrogen chloride gas
5.3. Advice for firefighters: Wear self-contained breathing apparatus for firefighting if necessary.
Wear protective clothing to prevent contact with skin and eyes.
6.1 Personal precautions, protective equipment and emergency procedures
Use personal protective equipment. Avoid dust formation. Avoid breathing vapours, mist or gas. Ensure adequate ventilation. Evacuate personnel to safe areas. Avoid breathing dust. For personal protection see section 8
6.2 Environmental precautions
Do not let product enter drains.
6.3 Methods and materials for containment and cleaning up
Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed containers for disposal
6.4 Reference to other sections: For disposal see section 13
7.1 Precautions for safe handling: Avoid contact with skin and eyes. Avoid formation of dust and aerosols. Provide appropriate exhaust ventilation at places where dust is formed. For precautions see section 2.2.
7.2 Conditions for safe storage, including any incompatibilities: Store in cool place. Keep container tightly closed in a dry and well-ventilated place. Store under inert gas. Hygroscopic.
7.3 Specific end use(s): Apart from the uses mentioned in section 1.2 no other specific uses are stipulated
9.2. Other safety information:
No data available
8.1 Control parameters:
Components with workplace control parameters: No data available
8.2 Exposure controls:
Appropriate engineering controls
Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.
Personal protective equipment:
Eye/face protection: Safety glasses with side-shields conforming to EN166 Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin protection: Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove’s outer surface) to avoid skin contact with this product. technique (without touching glove’s outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
The selected protective gloves have to satisfy the specifications of EU Directive 89/686/EEC and the standard EN 374 derived from it.
Body Protection: impervious clothing, the type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace
Respiratory protection
For nuisance exposures use type P95 (US) or type P1 (EU EN 143) particle respirator.For higher level protection use type OV/AG/P99 (US) or type ABEK-P2 (EU EN 143) respirator cartridges. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU)
Control of environmental exposure: Do not let product enter drains.
10.1 Reactivity: No data available
10.2 Chemical stability: Stable under recommended storage conditions.
10.3 Possibility of hazardous reactions: No data available
10.4 Conditions to avoid: Avoid moisture.
10.5 Incompatible materials: acids, Acid chlorides, Acid anhydrides, Oxidizing agents
10.6 Hazardous decomposition products:
Other decomposition products – no data available In the event of fire: see section 5
Information on toxicological effects
Acute toxicity: No data available
Skin corrosion/irritation: No data available
Serious eye damage/eye irritation: No data available
Respiratory or skin sensitisation: Prolonged or repeated exposure may cause allergic reactions in certain sensitive individuals. The preceding data, or interpretation of data, was determined using Quantitative Structure Activity Relationship (QSAR) modeling.
Germ cell mutagenicity: No data available
Carcinogenicity IARC : No component of this product present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed human carcinogen by IARC.
Reproductive toxicity: No data available
Specific target organ toxicity – single exposure: Inhalation – May cause respiratory irritation.
Specific target organ toxicity – repeated exposure: No data available
Aspiration hazard: No data available
Additional Information
RTECS: Not available
To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated.
not avaliable
13.1 Waste treatment methods:
Product: Burn in a chemical incinerator equipped with an afterburner and scrubber but exert extra care in igniting as this material is highly flammable. Offer surplus and no recyclable solutions to a licensed disposal company. Contact a licensed professional waste disposal service to dispose of this material.
Contaminated packaging: Dispose of as unused product.
No data available.
15.1 Safety, health and environmental regulations/legislation specific for the substance or mixture: No data available
15.2 Chemical Safety Assessment: For this product a chemical safety assessment was not carried out
The information above is believed to be accurate and represents the best information currently available to us.