Product Name | 2,6-Dihydroxy Acetophenone (CAS No.699-83-2) |
Structure | |
CAS No. | 699-83-2 |
Related to Pharma | Sodium Cromoglycate |
Molecular Formula | C8H8O3 |
Formula Weight | 152.15 |
Storage Condition | Ambient |
Description | Yellow to brownish crystalline powder |
Identification by HPLC | The retention time of test sample solution should match with that of working standard solution in the test impurities by HPLC. |
Impurities by HPLC | |
Purity | Not less than 99.00% |
Assay by HPLC (ODB) | Not less than 98.0% and Not more than 102.0% w/w |
Chemical Nam : 2,6-Dihydroxy AcetophenoneCAS No : 699-83-2 Molecular Weight : 152.15Chemical Formula : C8H8O3
Ingredient | CAS No | CONCENTRATION |
2,6-Dihydroxy Acetophenone | 699-83-2 | — |
4.1 Description of first aid measures
General advice General advice: Consult a physician. Show this safety data sheet to the doctor in attendance.
If inhaled: If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician
In case of skin contact: Wash off with soap and plenty of water. Consult a physician.
In case of eye contact: Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
If swallowed: Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
4.2 Most important symptoms and effects, both acute and delayed
The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in section 11.
4.3 Indication of any immediate medical attention and special treatment needed:
No data available
5.1. Extinguishing media: Use dry sand, dry chemical or alcohol-resistant foam for extinction.
5.2. Special hazards arising from the substance or mixture: Carbon monoxide, nitrogen oxides,
hydrogen fluoride, hydrogen bromide.
5.3. Advice for firefighters: Wear self-contained breathing apparatus for firefighting if necessary.
5.4. Further information: No data available.
6.1 Personal precautions, protective equipment and emergency procedures
Ensure adequate ventilation. Use personal protective equipment.
6.2 Environmental precautions
Should not be released into the environment. See Section 12 for additional ecological information
6.3 Methods and materials for containment and cleaning up
Sweep up or vacuum up spillage and collect in suitable container for disposal.
6.4 Reference to other sections: Refer to protective measures listed in Sections 8 and 13.
7.1 Precautions for safe handling: Avoid contact with skin and eyes. Avoid inhalation of vapor
or mist. Keep away from sources of ignition – No smoking. Take measures to prevent the buildup
of electro-static charge. For precautions see section 2.2
7.2 Conditions for safe storage, including any incompatibilities: Keep container tightly closed
in a dry and well-ventilated place at Ambient. Containers which are opened must be carefully
resealed and kept upright to prevent leakage.
7.3 Specific end use(s): Laboratory chemicals, for scientific research and development only.
8.1 Control parameters:
Components with workplace control parameters: Contains no substances with occupational
exposure limit values.
8.2 Exposure controls:
Appropriate engineering controls
Ensure that eyewash stations and safety showers are close to the workstation location. Ensure
adequate ventilation, especially in confined areas
Personal protective equipment:
Eye/face protection: Wear appropriate protective eyeglasses or chemical safety goggles as
described by OSHA’s eye and face protection regulations in 29 CFR 1910.133 or European
Standard EN166.
Skin protection: Handle with gloves. Gloves must be inspected prior to use. Use proper
glove removal technique (without touching glove’s outer surface) to avoid skin contact with
this product. Dispose of contaminated gloves after use in accordance with applicable laws and
good laboratory practices. Wash and dry hands
Body Protection: Complete suit protecting against chemicals, Flame retardant antistatic
protective clothing., The type of protective equipment must be selected according to the
concentration and amount of the dangerous substance at the specific workplace
Control of environmental exposure: Prevent further leakage or spillage if safe to do so. Do
not let product enter drains.
a) Appearance Solid
b) Odour Off-White to White color powder
c) Odour Threshold No data available
d) pH No data available
e) Melting point/freezing point 200 – 210◦C
f) Initial boiling point and boiling range No data available
g) Flash point No data available
h) Evaporation rate No data available
i) Flammability (solid, gas) No data available
j) Upper/lower flammability or explosive limits No data available
k) Vapour pressure No data available
l) Vapour density No data available
m) Relative density No data available
n) Water solubility No data available
o) Partition coefficient: n-octanol/water No data available
p) Auto-ignition temperature No data available
q) Decomposition temperature No data available
r) Viscosity No data available
s) Explosive properties No data available
t) Oxidizing properties No data available
9.2. Other safety information:
Formula C20H23FN2O2.BrH
Molecular weight 423.3
CAS Number 103146-26-5
10.1 Reactivity: No data available
10.2 Chemical stability: Stable under recommended storage conditions.
10.3 Possibility of hazardous reactions: No data available
10.4 Conditions to avoid: Not data available
10.5 Incompatible materials: Not data available
10.6 Hazardous decomposition products:
Hazardous decomposition products formed under fire conditions: Carbon monoxide, nitrogen
oxides, hydrogen flu-oride, hydrogen bromide.
No data available
Not available.